About the Tripp Lite SmartOnline SU3000LCD2UHVTF

View User Manual

2U Double-Conversion UPS Protects Equipment against Damage, Downtime and Data Loss

This 208V and 120V 60 Hz UPS system maintains perfect output by converting AC input to DC, then reconverting UPS output to fully regulated sine wave AC with +/-2% voltage regulation in both on-line and battery modes. Featuring a 2.7kW capacity, high 0.9 power factor, 570 joules of surge suppression, true on-line operation with pure sine wave output and zero transfer time in on-line double-conversion mode, the SmartOnline® SU3000LCD2UHVTF double-conversion UPS provides the highest level of AC power protection and battery backup for critical network closet, computer room and data center equipment. With the included 2U step-down transformer, this 3kVA UPS system can support both low- and high-voltage equipment.

Set Power Strategies to Reflect Your Protection Priorities

Pick your power strategy, from precise power for sensitive systems to the highest possible electrical efficiency, while ensuring 100% uptime. Choose from four selectable strategies: Max Efficiency, Max Quality, Frequency Regulation and Auto Adaptive, which automatically offers increased efficiency when utility power conditions are good and enhanced power quality when power conditions are poor.

Individually Controllable Load Banks Let You Access and Control Outlets Remotely

The UPS and transformer combined feature 20 outlets in total-12 unswitched NEMA 5-15/20R on the transformer, six NEMA 6-15/20R on the UPS and one unswitched NEMA L6-20R on each. Four NEMA 6-15/20R outlets are split into two switchable load banks, allowing you to reboot select components or shed loads remotely.

Reliable, Expandable Battery Backup Keeps You Operational Through Power Outages

The field-replaceable, hot-swappable internal battery provides 13.5 minutes of support at half load (1350W) and five minutes at full load (2700W), keeping protected equipment operational through power failures. For mission-critical applications demanding scalable extended runtime, the UPS supports "smart" external battery packs, such as Tripp Lite's BP72V18-2US (sold separately). Both the internal batteries and sensor-enabled external battery packs are automatically sensed and configured during installation and replacement to offer accurate remaining runtime during outages and battery-age notifications. The intelligent battery management system with temperature-compensated charging extends battery life.

Automatic Bypass Maintains Utility Output During Fault Conditions

Auto-bypass mode keeps connected equipment powered and operational, even during UPS fault conditions.

Automatically Turns Back On When Power Is Restored

Battery-independent restart ensures automatic UPS power-up without user interaction after lengthy power outages, even when batteries are expired and require replacement.

Intuitive Front-Panel Interface for Convenient UPS Operation and Monitoring

The front-panel LCD screen reports UPS operating mode, detailed UPS status and site-power information, as well as a variety of advanced UPS setup and configuration options. LEDs indicate AC input/output, battery and fault status.

Advanced Communications Ports Allow for Automatic Saves and Shutdowns

RS-232 and HID-compliant USB ports connect to a computer running Tripp Lite's free downloadable PowerAlert® software to enable safe unattended file saves and system shutdown in case of a prolonged power failure. An EPO port connects the UPS to a contact closure switch to enable emergency inverter shutdown. Cables are included.

2U Double-Conversion UPS Protects Equipment against Damage, Downtime and Data Loss

This 208V and 120V 60 Hz UPS system maintains perfect output by converting AC input to DC, then reconverting UPS output to fully regulated sine wave AC with +/-2% voltage regulation in both on-line and battery modes. Featuring a 2.7kW capacity, high 0.9 power factor, 570 joules of surge suppression, true on-line operation with pure sine wave output and zero transfer time in on-line double-conversion mode, the SmartOnline® SU3000LCD2UHVTF double-conversion UPS provides the highest level of AC power protection and battery backup for critical network closet, computer room and data center equipment. With the included 2U step-down transformer, this 3kVA UPS system can support both low- and high-voltage equipment.

Set Power Strategies to Reflect Your Protection Priorities

Pick your power strategy, from precise power for sensitive systems to the highest possible electrical efficiency, while ensuring 100% uptime. Choose from four selectable strategies: Max Efficiency, Max Quality, Frequency Regulation and Auto Adaptive, which automatically offers increased efficiency when utility power conditions are good and enhanced power quality when power conditions are poor.

Individually Controllable Load Banks Let You Access and Control Outlets Remotely

The UPS and transformer combined feature 20 outlets in total-12 unswitched NEMA 5-15/20R on the transformer, six NEMA 6-15/20R on the UPS and one unswitched NEMA L6-20R on each. Four NEMA 6-15/20R outlets are split into two switchable load banks, allowing you to reboot select components or shed loads remotely.

Reliable, Expandable Battery Backup Keeps You Operational Through Power Outages

The field-replaceable, hot-swappable internal battery provides 13.5 minutes of support at half load (1350W) and five minutes at full load (2700W), keeping protected equipment operational through power failures. For mission-critical applications demanding scalable extended runtime, the UPS supports "smart" external battery packs, such as Tripp Lite's BP72V18-2US (sold separately). Both the internal batteries and sensor-enabled external battery packs are automatically sensed and configured during installation and replacement to offer accurate remaining runtime during outages and battery-age notifications. The intelligent battery management system with temperature-compensated charging extends battery life.

Automatic Bypass Maintains Utility Output During Fault Conditions

Auto-bypass mode keeps connected equipment powered and operational, even during UPS fault conditions.

Automatically Turns Back On When Power Is Restored

Battery-independent restart ensures automatic UPS power-up without user interaction after lengthy power outages, even when batteries are expired and require replacement.

Intuitive Front-Panel Interface for Convenient UPS Operation and Monitoring

The front-panel LCD screen reports UPS operating mode, detailed UPS status and site-power information, as well as a variety of advanced UPS setup and configuration options. LEDs indicate AC input/output, battery and fault status.

Advanced Communications Ports Allow for Automatic Saves and Shutdowns

RS-232 and HID-compliant USB ports connect to a computer running Tripp Lite's free downloadable PowerAlert® software to enable safe unattended file saves and system shutdown in case of a prolonged power failure. An EPO port connects the UPS to a contact closure switch to enable emergency inverter shutdown. Cables are included.

Technical Specifications of the Tripp Lite SmartOnline SU3000LCD2UHVTF

General Information


Manufacturer Eaton Corporation
Manufacturer Part Number SU3000LCD2UHVTF
Manufacturer Website Address http://www.eaton.com
Brand Name Tripp Lite series
Product Line SmartOnline
Product Model SU3000LCD2UHVTF
Product Name SmartOnline SU3000LCD2UHVTF 3KVA Rack/Tower UPS
Product Type Double Conversion Online UPS

Technical Information


Plug / Connector Type NEMA L6-20P
Receptacle Type NEMA 5-15/20RNEMA 6-15/20RNEMA L6-20R
Receptacle Detail 6 x NEMA 6-15/20R12 x NEMA 5-15/20R2 x NEMA L6-20R
Transfer Time 0 ns
EMI / RFI Noise Filter Yes
Phase Single Phase
Energy Saving High Efficiency Economy Mode Operation; Individually Controllable Load Banks
Application / Usage Network EquipmentData CenterServerNetwork ClosetMission Critical EquipmentComputer Room

Power Description


Load Capacity (VA) 3000 VA
Load Capacity (Watt) 2700 W
Input Voltage 230 V AC
Output Voltage 120 V AC208 V AC
Output Frequency 60 Hz
Waveform Type Pure Sine Wave
Surge Energy Rating 570 J

Management


Network Management SNMP/DB9/USB
Alarm FaultPower FailureOverloadLow Battery

Controls/Indicators


Status Indicators

4 Front Panel LEDs:

  • AC Input (Green)
  • AC Output (Green)
  • Battery (Yellow)
  • Fault (Red)

Interfaces/Ports


Serial Port Yes
EPO Port Yes
USB (HID Compliant) Port Yes

Battery Information


DC System Voltage 72 V DC
Backup / Run Time (Full Load) 5 Minute
Backup / Run Time (Half Load) 13.50 Minute
Typical Battery Recharge Time 3 Hour
Hot Swappable Yes
Replaceable Battery Yes

Environmental Conditions


Maximum Operating Temperature 104°F (40°C)
Storage Temperature 5°F (-15°C) - 122°F (50°C)
Maximum Operating Elevation 9842.52 ft
Thermal Dissipation 273.44 W

Physical Characteristics


Height 6.97"
Width 17.32"
Depth 24.25"
Rack Height 4U
Form Factor Rack/Tower
Weight (Approximate) 133.82 lb

Miscellaneous


Package Contents
  • SmartOnline SU3000LCD2UHVTF 3KVA Rack/Tower UPS
  • SU5000XFMRT2U20 2U 208V to 120V Step-Down Isolation Transformer
  • USB Cable
  • DB9 Cable
  • EPO Cable
  • Rack-mounting Hardware
  • Owner's Manual
Green Compliant Yes
Country of Origin China
Environmental Compliance Restriction of Hazardous Substances (RoHS)

Warranty


Limited Warranty 2 Year

Ratings and Reviews