Tripp Lite PDU3EVN6L2120 45-Outlet PDU

Part #: 1-1637359

Tripp Lite PDU3EVN6L2120 45-Outlet PDU

Part #: 1-1637359 MFG Part #: PDU3EVN6L2120 UPC #: 037332206787
$1,543.00 $930.81
Save $612.19
SPECIAL ORDER

0 Available

(as of Apr 11, 2026 5:17 AM) Refresh Inventory
OVERSIZED / HEAVY ITEM

This is an oversized / heavy item and requires extra shipping and handling time.

AUTHORIZED DEALER
AUTHORIZED DEALER
AUTHORIZED DEALER

AUTHORIZED DEALER

Protect your investment ()

About the Tripp Lite PDU3EVN6L2120

View User Manual
5.8kW 3-phase PDU with multifunction touchscreen LCD distributes and monitors AC power in an IT or industrial environment.

Features
3-Phase 0U PDU Distributes and Monitors Network-Grade Power

Recommended for data centers, server rooms and network closets, this monitored power distribution unit provides real-time remote monitoring of voltage and load levels via built-in network connection. A six-foot (1.8-meter) cord with NEMA L21-20P input plug connects the 208V 3-phase PDU to a compatible AC power source, generator or protected UPS. The firmware can be easily upgraded to ensure the Tripp Lite vertical PDU continues to perform at its best.

45 Outlets Dispense AC Power to Connected Equipment

During normal operation, 36 C13 (208V), six C19 (208V) and three NEMA 5-15/20R (120V) outlets distribute AC power to rack equipment. The outlets are split into six individually monitored load banks-three banks containing two C19 and 12 C13 outlets and three of one 5-15/20R outlet each. Three LEDs monitor load conditions for each bank. Plug-lock insert sleeves for the C13 and C19 outlets are included to prevent connected cables from becoming accidentally dislodged.

Built-In LX Platform Network Management Card Allows Remote Access 24/7

The Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP. The 0U PDU can receive IP address assignments via DHCP server (automatic) or static (manual) method.

Color Touchscreen LCD Offers Important Data at a Glance

An easy-to-navigate color touchscreen LCD reports network data, including IP address, input current level per phase, and output current per load bank with ±1% billing-grade accuracy. It also generates a unique QR code to allow read-only access to the 0U PDU via mobile device. If an EnviroSense2 module is connected to the 3-phase PDU, the LCD also displays status and environmental data, such as temperature and humidity.

Easy to Install Vertically in an EIA-Standard 19 in. Rack

The 70-inch (178 cm) 0U PDU mounts vertically using the included toolless mounting buttons or the included rack-mounting brackets. Spare buttons are also included. Use the included PDUMVROTATEBRKT kit to install the 208V 3-phase PDU with outlets facing the rear for better airflow or equipment access.

TAA-Compliant for GSA Schedule Purchases

The PDU3EVN6L2120 is compliant with the Federal Trade Agreements Act (TAA), which makes it eligible for GSA (General Services Administration) Schedule and other federal procurement contracts.

More from the Manufacturer

5.8kW 3-phase PDU with multifunction touchscreen LCD distributes and monitors AC power in an IT or industrial environment.

Features
3-Phase 0U PDU Distributes and Monitors Network-Grade Power

Recommended for data centers, server rooms and network closets, this monitored power distribution unit provides real-time remote monitoring of voltage and load levels via built-in network connection. A six-foot (1.8-meter) cord with NEMA L21-20P input plug connects the 208V 3-phase PDU to a compatible AC power source, generator or protected UPS. The firmware can be easily upgraded to ensure the Tripp Lite vertical PDU continues to perform at its best.

45 Outlets Dispense AC Power to Connected Equipment

During normal operation, 36 C13 (208V), six C19 (208V) and three NEMA 5-15/20R (120V) outlets distribute AC power to rack equipment. The outlets are split into six individually monitored load banks-three banks containing two C19 and 12 C13 outlets and three of one 5-15/20R outlet each. Three LEDs monitor load conditions for each bank. Plug-lock insert sleeves for the C13 and C19 outlets are included to prevent connected cables from becoming accidentally dislodged.

Built-In LX Platform Network Management Card Allows Remote Access 24/7

The Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP. The 0U PDU can receive IP address assignments via DHCP server (automatic) or static (manual) method.

Color Touchscreen LCD Offers Important Data at a Glance

An easy-to-navigate color touchscreen LCD reports network data, including IP address, input current level per phase, and output current per load bank with ±1% billing-grade accuracy. It also generates a unique QR code to allow read-only access to the 0U PDU via mobile device. If an EnviroSense2 module is connected to the 3-phase PDU, the LCD also displays status and environmental data, such as temperature and humidity.

Easy to Install Vertically in an EIA-Standard 19 in. Rack

The 70-inch (178 cm) 0U PDU mounts vertically using the included toolless mounting buttons or the included rack-mounting brackets. Spare buttons are also included. Use the included PDUMVROTATEBRKT kit to install the 208V 3-phase PDU with outlets facing the rear for better airflow or equipment access.

TAA-Compliant for GSA Schedule Purchases

The PDU3EVN6L2120 is compliant with the Federal Trade Agreements Act (TAA), which makes it eligible for GSA (General Services Administration) Schedule and other federal procurement contracts.

More from the Manufacturer

Technical Specifications of the Tripp Lite PDU3EVN6L2120

General Information


Manufacturer Eaton Corporation
Manufacturer Part Number PDU3EVN6L2120
Manufacturer Website Address http://www.eaton.com
Brand Name Eaton
Product Model PDU3EVN6L2120
Product Name PDU3EVN6L2120 45-Outlet PDU
Product Type PDU

Technical Information


PDU Type Monitored
Phase Three Phase
Plug / Connector Type NEMA L21-20P
Plug / Connector Detail 1 x NEMA L21-20P
Receptacle Type NEMA 5-15/20RIEC 60320 C13IEC 60320 C19
Receptacle Detail 6 x IEC 60320 C1936 x IEC 60320 C133 x NEMA 5-15/20R

Power Description


Input Voltage 230 V AC
Output Voltage 120 V AC208 V AC
Power Rating (Watt) 5800 W
Input Current 16 A

Management


Management
  • IPv4
  • IPv6
  • HTTP
  • HTTPS
  • SMTP
  • SNMPv1
  • SNMPv2
  • SNMPv3
  • telnet
  • SSH
  • FTP
  • DHCP
  • NTP

Interfaces/Ports


Network (RJ-45) Yes

Physical Characteristics


Mounting Orientation Vertical
Mount Type Rack-mountable
Rack Height 0U
Height 70"
Width 2.2"
Depth 2.5"
Weight (Approximate) 13.50 lb

Miscellaneous


Package Contents
  • PDU3EVN6L2120 45-Outlet PDU
  • Built-in LX Platform Interface
  • Configuration Cable
  • 42 x Plug-lock Insert Sleeves
  • Rack-mounting Hardware
  • Spare Mounting Buttons
  • PDUMVROTATEBRKT Mounting Bracket Accessory
  • Owner's Manual
Green Compliant Yes
Country of Origin Taiwan
TAA Compliant Yes
Environmental Compliance Restriction of Hazardous Substances (RoHS)

Warranty


Limited Warranty 2 Year